FY3224S (FY3200S-24M) Generador de señales de función DDS de forma de onda arbitraria de doble canal de 24 MHz Contador de barrido de onda sinusoidal cuadrada
* Estimated delivery times start from the date of shipment, excluding processing time.
* Actual delivery times may vary due to holidays, weather conditions, or customs delays.
Envío estándar gratis en pedidos superiores a $9.9
Política de devolución
Los artículos devueltos serán aceptados dentro de los 40 días posteriores a la recepción de los productos. Los artículos personalizados no se pueden devolver ni cambiar. Los artículos comprados con una tarjeta de regalo electrónica solo son intercambiables; no se aplican reembolsos.
Regalo gratis
Bienvenido a Roymall, tu sitio web profesional para comprar regalos de tiendas departamentales premium. Valoramos y apreciamos mucho tu apoyo, y queremos expresar nuestra gratitud agregando un toque extra de emoción a tus compras. Cuando compras con nosotros, no solo disfrutas de productos de alta calidad que mejoran tu estilo de vida, sino que también recibirás un regalo exclusivo con cada pedido que realices. ¿Listo para explorar nuestra colección y encontrar tus regalos perfectos? Navega por nuestra selección de artículos de tiendas departamentales premium, realiza tu pedido y espera con ansias la emoción de recibir tu regalo gratis junto con tu compra.
Política de envío
Trabajaremos duro para entregarte los artículos después de recibir tus pedidos y asegurarnos de que lleguen de manera segura. Los detalles de entrega se proporcionarán en tu correo de confirmación.En la mayoría de los casos, los pedidos se procesan en 2 días. En circunstancias especiales, se retrasará de la siguiente manera: Cuando realices un pedido el sábado, domingo o días festivos, se retrasará 2 días.Normalmente, se necesitan de 5 a 7 días hábiles (de lunes a viernes) sin verse afectado por retrasos en los vuelos u otros factores ambientales.Debido a que nuestro servicio de envío es mundial, los tiempos de entrega dependerán de tu ubicación, por lo que puede tardar unos días y te pedimos paciencia si estás en distritos o países remotos.
1. Política de devolución y cambio
Solo aceptamos artículos comprados en roymall.com. Si compras a través de nuestros distribuidores locales u otros minoristas, no puedes devolverlos con nosotros.Los artículos de venta final o regalos gratuitos no son aceptables para devolución.Para ser elegible para una devolución, tu artículo debe estar sin usar y en las mismas condiciones en que lo recibiste. También debe estar en su empaque original.Después de recibir las instrucciones de devolución de nuestra parte, por favor empaqueta tus artículos devueltos y deja tu paquete en la oficina de correos local o en otro servicio de mensajería. Procesaremos tu devolución o cambio de artículo en un plazo de 3 a 5 días hábiles después de recibirlo. El reembolso se procesará y acreditará automáticamente en tu método de pago original.No se aceptan devoluciones ni cambios si el producto fue producido a medida, incluido tamaño personalizado, color personalizado o impresión personalizada.¿Necesitas más ayuda? Contáctanos. service@roymall.com o Whatsapp: +8619359849471
2. Política de reembolso
Recibirás un reembolso completo o un crédito de tienda del 100% después de que recibamos y verifiquemos el paquete devuelto. El reembolso se procesará y acreditará automáticamente en tu método de pago original.Ten en cuenta que los costos de envío y cualquier impuesto o tarifa no son reembolsables. Los costos de envío adicionales no son reembolsables una vez que el paquete ha sido enviado. Eres responsable de pagar estas tarifas y no podemos exonerarlas ni reembolsarlas, incluso si el pedido nos es devuelto.Una vez que recibamos y confirmemos tu artículo devuelto, te enviaremos un correo electrónico para notificarte que hemos recibido tu artículo devuelto. También te notificaremos la aprobación o el rechazo de tu reembolso.Si tienes algún problema con el proceso de reembolso, contáctanos. service@roymall.com o Whatsapp: +8619359849471
Description:
FY3224S 24MHz Dual-channel Arbitrary Waveform DDS Function Signal Generator Sine Square Wave Sweep Counter
Features:
Output signal frequency high accuracy, good stability. Signal amplitude up to 20Vpp. Instrument can realize the adjustment program of function parameters , easy to use. Accompanying frequency meter, counter function, high cost. The instrument can output sine, square, triangle, ramp, pulse, staircase, DC voltage waveform. Pulse wave pulse width precision can be adjustable.
Function:
1. Using DDS direct digital synthesis technology to generate precise, stable, low distortion output signal. 2. CH1 and CH2 completely symmetrical two channels, each channel can be independently set the parameters. 3. Supports user-defined waveforms, each arbitrary waveform memory depth 2048 x 12bits, 250MSa / s sampling rate. 4. Has burst burst output, selectable manual trigger, internal and external trigger CH2 trigger three trigger modes that allow the unit to any output 1 - 1048575 bursts. 5. Measurement functions: instrument comes with 100MHz frequency counter functions and pulse counter functions. 6. Waveform generator up to 12 bits wide, the output waveform is more delicate, waveform distortion is reduced magnitude. 7. With full CNC functions, display and digital adjustment phase current amplitude of the output signal, offset, frequency, duty cycle, and the two signals. 8. After connecting the instrument to the computer, you can use the computer through the PC control signal generator functions and parameters, and can be edited on a computer to download arbitrary waveform output waveform to the instrument.
9. Communication: serial communication, protocol completely open, user-friendly secondary development. 10. High frequency accuracy: frequency accuracy up to 10-6 magnitude. 11. High frequency resolution: the full range of frequency resolution 10mHz. 12. Tracking function: built-in frequency, amplitude, offset, duty cycle, waveform and other parameters follow function, easy to use. 13. Scanning features: a frequency linear sweep and logarithmic sweep function, scan start and end points can be set. 14. Storage feature: You can store 20 groups instrument state parameters set by the user, can be called up to Reproduce 15. Operation: key operation, LCD1602 LCD display in English, direct digital setting parameters or continuous adjustment knob. 16. Input voltage protection: extended power input range AC85V to AC240V wide voltage. 17. Output short circuit protection: All signal outputs can operate at over load short circuit 60S.
Technical Parameters: Built-in switching power supply: AC85V-AC260V Interface: USB
Signal output: Output amplitude: ≥≥20Vp-p (no load) Output Impedance: 50u03a9 ± 10% DC polarization: ± 10V Frequency range: 0Hz - 24MHz (orther 0Hz - 6MHz)
Scan function: Scanning mode: Linear sweep, logarithm scanning Frequency Range: Start and end points set arbitrary Frequency scanning range: M1 - M2 predetermined frequency Scan rate: 1s ~ 999s / step
Other: Storage and transferred functions: M0 - M9 (M0: default) Size: 200mm (L) x 190mm(W) x 90mm(H) Beeper function: to set open or closed by the program Operating characteristics: All key operation, continuous adjustment knob Environmental conditions: Temperature 0 - 40 ℃ humidity <80%
Good news:
The unit is working. Controls is rather friendly and intuitive clear. FW ver.4.1. On the whole it conforms to the description.
Bad news:
- Bad packing, inappropriate for post delivery. The unit box looks as if elephants have danced on it.
- Mains cable is with crappy chinese plug, not European standard. No adaptor even included.
- Switching power supply is a total crap. You have to replace it with a classic linear one.
- Dangerous high voltage leakage from PS. The voltage between generator’s ground parts of all BNC and mains earth (or other laboratory equipment ) is 100VAC. You may easy get an electric shock and fry delicate equipment and microchips.
- Sin wave has glitches at the zero crossing point and half way long
- At 20VAC output waveforms are intact below 5MHz, at higher frequencies waveforms are significantly corrupted
- At 24MHz the amplitude significantly decreases
- You can get usable waveforms only below 5Mhz and below 10VAC of output
Conclusion:
A good generator for testing audio and some TV equipment, not suitable for ham radio.
Good news:
The unit is working. Controls is rather friendly and intuitive clear. FW ver.4.1. On the whole it conforms to the description.
Bad news:
- Bad packing, inappropriate for post delivery. The unit box looks as if elephants have danced on it.
- Mains cable is with crappy chinese plug, not European standard. No adaptor even included.
- Switching power supply is a total crap. You have to replace it with a classic linear one.
- Dangerous high voltage leakage from PS. The voltage between generator’s ground parts of all BNC and mains earth (or other laboratory equipment ) is 100VAC. You may easy get an electric shock and fry delicate equipment and microchips.
- Sin wave has glitches at the zero crossing point and half way long
- At 20VAC output waveforms are intact below 5MHz, at higher frequencies waveforms are significantly corrupted
- At 24MHz the amplitude significantly decreases
- You can get usable waveforms only below 5Mhz and below 10VAC of output
Conclusion:
A good generator for testing audio and some TV equipment, not suitable for ham radio.
Good news:
The unit is working. Controls is rather friendly and intuitive clear. FW ver.4.1. On the whole it conforms to the description.
Bad news:
- Bad packing, inappropriate for post delivery. The unit box looks as if elephants have danced on it.
- Mains cable is with crappy chinese plug, not European standard. No adaptor even included.
- Switching power supply is a total crap. You have to replace it with a classic linear one.
- Dangerous high voltage leakage from PS. The voltage between generator’s ground parts of all BNC and mains earth (or other laboratory equipment ) is 100VAC. You may easy get an electric shock and fry delicate equipment and microchips.
- Sin wave has glitches at the zero crossing point and half way long
- At 20VAC output waveforms are intact below 5MHz, at higher frequencies waveforms are significantly corrupted
- At 24MHz the amplitude significantly decreases
- You can get usable waveforms only below 5Mhz and below 10VAC of output
Conclusion:
A good generator for testing audio and some TV equipment, not suitable for ham radio.
I bought this unit to replace an earlier model. This model has remote facilities which I wanted to use for automatic testing.
These are the problems:
1) The upper frequency limit is 24MHz but you cannot set the frequency directly to more than 9.999999 using the <> buttons and the dial. You have to go to the units MHZ position and just keep turning and you will go over 10MHz. When you do this the 0.01KHz position disappears too. - see photos
2) Related to 1) the display software has a bug in it. If you program 10MHz the last digit (0.01KHz) disappears. You can still set the lowest digit but it does not show. Sometimes you also get the display 999.9999kHzz - clearly a problem. The good news is the actual output seems to be ok.
3) The included disk includes the Host Communication Protocol V1.2 document. Either this is an earlier document or it is incomplete. as:
a) There is no command to set the frequency above 9.99999999. The command size limit for the frequency is 9 characters which means you cannot enter 10MHz or more using the serial command.
b) The specification says that there is are four downloadable 2048 point waveforms. The serial specification does not include the protocol to do this. This is a feature I wanted for my project.
4) The included software is all in Chinese and is useless.
If you only want to use this unit standalone then it is excellent value for money. If you really need to drive this unit using the serial interface then the information is incomplete.
I bought this unit to replace an earlier model. This model has remote facilities which I wanted to use for automatic testing.
These are the problems:
1) The upper frequency limit is 24MHz but you cannot set the frequency directly to more than 9.999999 using the <> buttons and the dial. You have to go to the units MHZ position and just keep turning and you will go over 10MHz. When you do this the 0.01KHz position disappears too. - see photos
2) Related to 1) the display software has a bug in it. If you program 10MHz the last digit (0.01KHz) disappears. You can still set the lowest digit but it does not show. Sometimes you also get the display 999.9999kHzz - clearly a problem. The good news is the actual output seems to be ok.
3) The included disk includes the Host Communication Protocol V1.2 document. Either this is an earlier document or it is incomplete. as:
a) There is no command to set the frequency above 9.99999999. The command size limit for the frequency is 9 characters which means you cannot enter 10MHz or more using the serial command.
b) The specification says that there is are four downloadable 2048 point waveforms. The serial specification does not include the protocol to do this. This is a feature I wanted for my project.
4) The included software is all in Chinese and is useless.
If you only want to use this unit standalone then it is excellent value for money. If you really need to drive this unit using the serial interface then the information is incomplete.
I bought this unit to replace an earlier model. This model has remote facilities which I wanted to use for automatic testing.
These are the problems:
1) The upper frequency limit is 24MHz but you cannot set the frequency directly to more than 9.999999 using the <> buttons and the dial. You have to go to the units MHZ position and just keep turning and you will go over 10MHz. When you do this the 0.01KHz position disappears too. - see photos
2) Related to 1) the display software has a bug in it. If you program 10MHz the last digit (0.01KHz) disappears. You can still set the lowest digit but it does not show. Sometimes you also get the display 999.9999kHzz - clearly a problem. The good news is the actual output seems to be ok.
3) The included disk includes the Host Communication Protocol V1.2 document. Either this is an earlier document or it is incomplete. as:
a) There is no command to set the frequency above 9.99999999. The command size limit for the frequency is 9 characters which means you cannot enter 10MHz or more using the serial command.
b) The specification says that there is are four downloadable 2048 point waveforms. The serial specification does not include the protocol to do this. This is a feature I wanted for my project.
4) The included software is all in Chinese and is useless.
If you only want to use this unit standalone then it is excellent value for money. If you really need to drive this unit using the serial interface then the information is incomplete.
Tips:For questions about your order, place of delivery, product discount, taxation, delivery time, warranty, shipping, payment, exchange rate, and other questions unrelated to the product, please contact customer service.
showing 1-30 of 32|
Show Original
A part of the QA has been auto-translated.
0
Q:
Can you generate the same type of wave on both channels simultanously? Like sine wave 1 Khz on bith channels at the same time for example?
Can you generate the same type of wave on both channels simultanously? Like sine wave 1 Khz on bith channels at the same time for example?
The utility on the attached disk cannot be run or installed on my own computer (Win. 10). How, where, and from whom can I buy software that allows me to control the generator with the computer?
The utility on the attached disk cannot be run or installed on my own computer (Win. 10). How, where, and from whom can I buy software that allows me to control the generator with the computer?
You can check the link to find more information about banggood policy. https://www.banggood.com/Insurances_hl69_at650
You can check the link to find more information about banggood policy. https://www.banggood.com/Insurances_hl69_at650
Answered by Sniftywas on 05/11/2020Helpful (0)
0
Q:
I need to generate 10 MHz square wave in the range of -1 V to 1 V, does that equipment do that? I need to generate 10 MHz square wave between -1 V to 1 V, does this equipment produce it?
Preciso gerar onda quadrada de 10 MHz no intervalo de -1 V até +1 V, esse equipamento faz isso? I need to generate 10 MHz square wave between -1 V to +1 V, does this equipment produce it?
I need to generate 10 MHz square wave in the range of -1 V to 1 V, does that equipment do that?
I need to generate 10 MHz square wave between -1 V to 1 V, does this equipment produce it?
Preciso gerar onda quadrada de 10 MHz no intervalo de -1 V até +1 V, esse equipamento faz isso?
I need to generate 10 MHz square wave between -1 V to +1 V, does this equipment produce it?
The DC offset is +- 10v. But what is the minimum and maximum amplitude range in which 10v offset can be achieved? This is a 24MHz generator but no information on DC offset range is given. Only offset value is provided.
The DC offset is +- 10v. But what is the minimum and maximum amplitude range in which 10v offset can be achieved? This is a 24MHz generator but no information on DC offset range is given. Only offset value is provided.
The utility on the included disk cannot be run or installed on my own computer (Win. 10). How, where, and from whom can I buy software that allows me to control the generator with the computer?
The utility on the included disk cannot be run or installed on my own computer (Win. 10). How, where, and from whom can I buy software that allows me to control the generator with the computer?
The instrument arrived in good condition. The functions and operating modes work, that's good.
The instrument arrived in good condition. The functions and operating modes work, that's good.<br/>However: can't the software or application included on the CD be installed? What could be the problemjQuery111308819895488010372_1708106353728?? Disk error, software error, old software,...?<br/>I am attaching the state after starting the .exe file (screenshot) and the location of the folders and programs on the disk.<br/> Please help! Who can I contact for a solution? Who could install the program and does it work properly?<br/>__ And unfortunately I couldn't upload the screenshots either, even though I made both .jpg and .png files. The website did not allow it here, nor did it allow the comment to be sent.
The instrument arrived in good condition. The functions and operating modes work, that's good.
The instrument arrived in good condition. The functions and operating modes work, that's good.<br/>However: can't the software or application included on the CD be installed? What could be the problemjQuery1113009419455113622655_1708102510888?? Disk error, software error, old software,...?<br/>I am attaching the state after starting the .exe file (screenshot) and the location of the folders and programs on the disk.<br/> Please help! Who can I contact for a solution? Who could install the program and does it work properly?<br/>__ And unfortunately I couldn't upload the screenshots either, even though I made both .jpg and .png files. The website did not allow it here, nor did it allow the comment to be sent.
<br/>605 / *****<br/>Fordítási találatok<br/>Fordítási találat<br/>The instrument arrived in good condition. The functions and operating modes work, that's good.<br/>However: can't the software or application included on the CD be installed? What could be the problemjQuery111309003741943800612_1708099754385?? Disk error, software error, old software,...?<br/>I am attaching the state after starting the .exe file (screenshot) and the location of the folders and programs on the disk.<br/> Please help! Who can I contact for a solution? Who could install the program and does it work properly?<br/>__ And unfortunately I couldn't upload the screenshots either, even though I made both .jpg and .png files. The website did not allow it here, nor did it allow the comment to be sent.